SECTION I - COOLING TOWERS
- MyCRO TCB
#091164
- Automatic microprocessor controller with a wide range of
setup programmability for feed and bleed based on
conductivity recirculating water systems such as cooling
towers, spray ponds and evaporative condensers. Easy to
use keypad, set point from 200 to 20,000 microsiemens, 1
to 15 percent selectable deadband, Hi-Lo and bleed time
alarms, and digital display in degrees Fahrenheit or
Celsius. Programmable chemical inhibitor feed includes
limit time, percentage time, reset time and bleed
tracking methods. Thirty-two event biocide control for up
to 3 pumps with maximum four week cycle and bleed lockout
time up to 19 hours and 59 minutes, RS-485 port for
network operation with up to 30 total MyCRO devices. PC
status, setup, edit and test functions available from
supervisory PC. Nema 4X enclosure, receptacle cords.
#091191 MyCRO TCB with #015439 Plumbing Assembly
- MyCRO Network Kit
#055691
- 3.5" diskette for IBM or clone computer, RS-485 to
RS-232 converter and power supply, includes cable and
plug adapter. Installation permits network operation for
up to 30 units in a shielded, twisted pair loop of up to
4000 feet. System status, setup, edit and test functions
available for any MyCRO in the network from supervisory
PC.
- BPT - BIOCIDE PUMP/TIMER WITH LOCKOUT
#035420
- 8.5 oz./min. peristaltic pump designed to inject biocide
into a cooling tower basin according to preset start
times and amounts. BPT will "lockout" system
bleed during biocide feed or for up to o 8 hours
following feed. 7 day program with up to 9 injections per
day. Digital timer with 5 year battery backup, 115 VAC
plug-in, in stainless steel cabinet and installation kit.
- DR-1000
- A real time, microprocessor controlled event timer and
SnapHead™ pump in a stainless steel cabinet for
chemical treatment. It can be operated from 115V, 60 Hz.
or 230V, 50Hz. line power, or with a 6V DC lantern
battery. Setup is performed through a program/run
selector switch and 4 programming buttons with the aid of
a circuit board mounted LCD and internal instruction
label. An optional low level alarm may be added when
additional components are installed on the PCB.
- HyDAC Jr. (Feed and Bleed based on Conductivity)
#059787
- HyDAC Jr. includes 0-5,000 microsiemens/cm controller,
Nema 4X enclosure, dial set point, 115 VAC, 60 Hz., and
receptacle cord for pump. (Probe supplied separately.)
#090108 Same as #059787, but with 0-1000 microsiemens/cm.
controller.
- I.P.C. (Feed and Bleed based on Conductivity)
#016016
- IPC Integral Pump and Controller includes 10 GPD pump,
300-5,000 microsiemens/cm, dial set pint controller,
single painted enclosure for pump and controller, 115
VAC, 60 Hz. (Probe supplied separately.)
- I.P.W. (Feed and Bleed based on Water Meter
Measurement)
#016014
- IPW Integral Pump and Timer 115 VAC, 60 Hz, 20 GPD pump.
(Water meter required - order separately.) Single painted
enclosure for timer and pump, standard timer setting 18
seconds. *
* Special settings available (6 - 60 seconds in 6 second
increments).
- I.P.T. (Feed and Bleed based on Percentage Time)
#016325
- IPT Integral Pump and Percentage Timer 115 VAC, 60 Hz, 20
GPD Pump. Single painted enclosure for timer and pump.
Timer range: 10 minute cycle.
- MODEL "10" (Feed and Bleed based on
Conductivity, Biocide based on real-time clock)
#016120
- Model "10" is an Omni-View II with timing
circuit and Bio-Max II controller in one painted steel
enclosure. Conductivity control from 0-2,000 and 0-20,000
microsiemens/cm. Biocide controller activates two feed
pumps on an alternating basis. Bleed and chemical feed
pumps are locked-out during biocide pumping periods, 115
VAC, 60 Hz, output 14.5 amps. (Probe supplied
separately.)
#050712 Same as 016120 with piping assembly #015439.
- OMNI-VIEW II (Feed and Bleed based on
Conductivity)
#059785
- Omni-View II Controller receptacle cord model, Nema 4X
enclosure, 10 amp relay, digital display with timing
circuit (may be used as limit timer, precision reset
timer or percentage timer), recorder output, 120 VAC, 60
Hz-Range 0-2,000 and 0-20,000 microsiemens, with power
cord. (Probe supplied separately.)
- OMNI-VIEW II (Feed and Bleed based on
Conductivity)
#090101
- Omni-View II Controller conduit model, Nema 4X enclosure,
10 amp relay, digital display with timing circuit, (may
be used as limit timer, precision timer or percentage
timer), recorder output, 115 VAC, 60 Hz (order probe
separately) - Range 0-2,000 and 0-20,000 microsiemens.
- PRECISION RESET TIMER--PRT (Dual Output Based on
Water Meter Measurement)
#090109
- PRT Dual Timer, Nema 4X enclosure, 115 VAC, 60 Hz (timers
adjust in 1 second increments from 1-255 seconds). Timer
is wired for simultaneous operation; may be changed to
sequential operation in the field. Equipped with built-in
accumulator which stores 1-255 water meter signals, with
receptacle cord and power cord.
- BIO-MAX II SYSTEM
#059790
- Digital 24 hour clock microprocessor electronics,
illuminated "Week 1, Week 2, Pump A, Pump B and
Lock-Out" indicators, pump primer switch receptacle
model for pumps and bleed controller, battery backup,
Nema 4X enclosure, padlockable hasp, full view door, 115
VAC, 60 Hz, 20 amp relay with receptacle cord.
- PROBES AND PRE-PLUMBED ASSEMBLIES
- .
- CONDUCTIVITY (Probe Assembly Only)
- #035195- Drop-in/Screw-type- 2.2 -1"NPT -150 psi
-115 F PVC with tee
#028473 Conductivity probe 0.1 3/4" NPT 150 psi 115
F (pin-type) with tee,
#028454 SAFE "T" Pin-Type, 2.2 3/4" NPT
150 psi 115 F PVC with tee
#015421 SAFE "T" Pin-Type, 2.2 1" NPT 300
psi 150 F Hi-Pressure plated steel tee
#014200 Flow-thru bass 2.2 3/8" Ftg. 100 psi 150 F
#014948 Drop-in, brass body 2.2 N/A N/A 150 F
Conductivity Piping Assembly (Includes probe, flow switch
and sample petcock)
#015438 Flow-thru, CPVC (pin-type) 2.2 3/4" NPT 150
psi 150 F
#015439 Flow-thru, PVC (pin-type) 2.2 3/4" NPT 150
psi 115 F
- REPLACEMENT PROBES (for use with Tower
Controllers)
- #013322 Conductivity Probe only (pin type), 2.2 cell
constant.
#013324 Conductivity Probe only (pin-type), 0.1 cell
constant.
Note: For probe cord lengths other than standard,consult
factory
- SOLENOID VALVES AND ASSEMBLIES
- #030283 - 3/4" Valve (zero pressure), 115 VAC, 125
psi.
#030333 - 1" Valve, 115 VAC, 60 Hz, 125 psi.
#027035- 3/4" -Valve, 115 VAC, 60 Hz, 25 psi.
#014790 Tower Bleed Valve Assembly (includes 3/4"
solenoid valve, 3/4" "Y" strainer, globe
valve and (2) 3/4" unions) 125 psi.
- "Y" SCREEN STRAINERS
- #025409 3/8" Cast Iron
#034669 3/4" Cast Iron
#026530 1" Cast Iron
#030315 1-1/2" Cast Iron
- FLOW REGULATORS
- #030167 2 GPM
#030092 4 GPM
#030093 8 GPM
#027102 12 GPM
#030160 15 GPM
#030278 20 GPM
#030279 25 GPM
#030280 30 GPM
#032078 40 GPM
- WATER METERS
- .
- WATER METERS with electrical contacting head and
fittings rated at 150 psi @ 125 F (50 C).
- #057935 3/4", 20GPM, 1 pulse every 10 gal.
#057929 1", 50 GPM, 1 pulse every 10 gal.
#054426 1 1/2", 100 GPM, 1 pulse every 100 gal.
#053764 2", 130 GPM, 1 pulse every 100 gal.
- WATER METERS without electrical contacting head,
with fittings rated at 150 psi @ 125 F (50 C).
- #054455 3/4", 20 GPM
#054482 1", 50 GPM
#054424 1 1/2", 100 GPM
#054417 2", 130 GPM
- WATER METERS with electrical contacting head and
fittings rated at 150 psi @ 194 F (90 C).
- #05793 13/4", 20 GPM, 1 pulse every 10 gal.
#057930 1", 50 GPM, 1 pulse every 10 gal.
Note: Larger water meters, with and without contacting
heads, are available. Contact our Customer Service
Department.
- AUXILIARY EQUIPMENT
#012581 Test Module.
- #011012 Injection Point Fitting, 3/8".
#028112 Foot Valve Strainer, 3/8".
#034911 Clean-Out Brush for 3/8" flow-thru probe.
#034888 Accumulator - Used to store "counts"
from electrical contacting head water meter before
activating chemical feed pumps/valve, 12 VDC.
#014829 Level float switch (MyCRO TCB).
#051704 Replacement contacting head switch, with black
housing, for Water Meter.
#029716 Replacement contacting head switch, for Master
Meter.