SECTION II - BOILERS

MyCRO BBC
#091172
Automatic microprocessor controller with a wide range of setup programmability for surface blowdown and feed based on conductivity in most types of boilers. Easy to use keypad, intermittent or continuous sampling, temperature compensation option, set point from 200 to 20,000 microsiemens, 1 to 15 percent selectable deadband, Hi-Lo and blowdown time alarms, and degrees F or C digital display. Programmable pump timers, for up to 3 pumps, include percentage time and reset time methods. RS-485 port for network operation with up to 30 total MyCRO devices. System status, setup, edit and test functions available from supervisory PC, Nema 4X enclosure. (Probe supplied separately.)

MyCRO NETWORK KIT
#055691
3.5" diskette for IBM or clone computer, RS-485 to RS-232 converter and power supply, includes cable and plug adapter. Installation permits network operation for up to 30 MyCRO units in a shielded, twisted pair loop of up to 4000 feet. System status, setup, edit and test functions available for any MyCRO unit in the network from supervisory PC.

BOILER-MATIC 100M (Bleed Based on Intermittent Conductivity Sampling. Modu-Max Components)
#015240 Boiler-Matic 100M Controller only, bargraph display 0-10,000 microsiemens/cm; conduit model, painted steel enclosure, 115 VAC, 60 Hz. (Order probe separately.)
#015242 Boiler-Matic 100M Controller only (Modu-Max), same as #015240 but with 0-5,000 microsiemens. (Probe supplied separately.)

BOILER-MATIC 3000 (Bleed Based on Intermittent Conductivity Sampling)
#059789 Boiler-Matic 3000, dial set point, Nema 4X enclosure, 0-7,000 microsiemens/cm, 115VAC, 60 Hz. (Order probe separately.)
#090111 Same as #059789 but 240 VAC. 535.00

BOILER-MATIC 4000 (Bleed Based on Continuous Conductivity Sampling)
#059788 Boiler-Matic 4000, dial set point, Nema 4X enclosure, 0-7,000 microsiemens/cm, 115 VAC, 60 Hz. (Order probe separately.)

I.P.W. (Blowdown and Feed Based on Water Meter Measurement)
#016014
I.P.W. Integral Pump and Timer, 115 VAC, 60 Hz, 20 GPD pump. Water Meter required -- order separately. Single painted enclosure for timer and pump, standard timer setting 18 seconds.*
* Special settings available (6-60 seconds range in 6 sec. increments - for modification consult factory).

OMNI-VIEW II (For Condensate)
#059786
Omni-View II Controller only for condensate monitor-dump system, digital readout 0-200 microsiemens/cm, conduit model, 115 VAC, 60 Hz. Nema 4X enclosure, with receptacle cord. (Order probe separately
#0162412 Probe for condensate monitor, 0.1 cell constant, temperature compensated.

PRECISION RESET TIMER - PRT (Dual Output Based on Water Meter Measurement
#090109
PRT Dual Timers, Nema 4X enclosure, 115 VAC, 60 Hz (timers adjustable in 1 second increments from 1-255 secs.). Timers wired for simultaneous operation; may be changed to sequential operation in the field. Equipped with built-in accumulator which can store 1-255 water meter signals. Other time settings available, with receptacle cord.

PROBES
#059849 Conductivity Probe and Tee Assembly, rated 600 psi WSP, 3/4" NPT, SST
#051643 Same as 059849, but with 3" extension, without tee.
#051644 Same as 059849, but with 12" extension, without tee.
#051642 Probe, Rod and Bushing Assembly, rated 600 psi WSP (inserted into sample line), SST 316.
#091836 Probe, high temp. with temperature compensation. Cell constant k=1.0.

VALVES AND PRE-PLUMBED ASSEMBLIES
#014792 3/4" Motor Operated Valve, rated 250 psi WSP with orifice kit, 115 VAC, 60 Hz.
#034757 3/4" Motor Operated Valve, rated 250 psi WSP with orifice kit, probe and tee assembly, 115 VAC, 60 Hz.
#031211 3/4" Motor Operated Valve and Actuator only, rated 250 psi WSP, 115 VAC, 60 Hz.
#027042 1/2" Electric Solenoid Valve, rated 125 psi WSP, 115 VAC, 60 Hz.
#034756 1/2" Electric Solenoid Valve Assembly, complete with probe and tee, strainer and orifice kit, rated 125 psi WSP, 115 VAC, 60 Hz.
#028456 3/4" Electric Solenoid Valve, rated 250 psi, 115 VAC, 60 Hz (not recommended for pressure below 50 psi).
#028448 3/4" Electric Solenoid Valve Assembly, rated 250 psi, complete with probe and tee, strainer and orifice kit, 115 VAC, 60 Hz.

WATER METERS
.

WATER METERS with electrical contacting head and fittings rated at 150 psi @ 125 F (50 C).
#057935 3/4", 20 GPM, 1 pulse every 10 gal.
#057929 1", 50 GPM, 1 pulse every 10 gal.
#054426 1 1/2", 100 GPM, 1 pulse every 100 gal.
#053764 2", 130 GPM, 1 pulse every 100 gal.

WATER METERS without electrical contacting head, with fittings rated at 150 psi @ 125 F (50 ).
#054455 3/4", 20 GPM.
#054482 1", 50 GPM.
#054424 1 1/2", 100 GPM.
#054417 2", 130 GPM.

WATER METERS with electrical contacting head and fittings rated at 150 psi @ 194 F (90 C).
#057931 3/4", 20 GPM, 1 pulse every 10 gal.
#057930 1", 50 GPM, 1 pulse every 10 gal.

AUXILIARY EQUIPMENT
#034932 Sample Cooler, Type 316, Stainless Steel coil, shell rating 300 psi @ 200 F.; coil rating 1200 psi @ 750 F.
#014657 Sample Cooler, Copper Coil, shell rating 300 psi @ 200 F; coil rating 300 psi @ 300 F.
#034669 Strainer, 3/4" (recommended when using solenoid valve), cast iron.
#012391 Alarm Bell, 115 VAC.
#015300 Orifice Kit, union with (3) drilled beveled tab orifices plates and (1) blank plate.
#014849 Transfer Switch (for use w/two boilers ).